About Wirebench Pro
Precision electrical engineering calculators and searchable code reference tables built for electricians, engineers, inspectors, and contractors.
Designed like a bench instrument
Wirebench Pro (https://wirebenchpro.com) provides 24 interactive electrical calculators and 6 searchable reference tables covering conductor sizing, voltage drop, ampacity derating, conduit fill, overcurrent protection, grounding, and equipment circuits. Every tool is designed to behave like a calibrated field instrument: inputs update results instantaneously, every code assumption is stated next to the reading, and every calculation can be shared by URL or printed onto a single job-site worksheet.
Whether you are sizing a 480 V three-phase industrial feeder with AC reactance in steel conduit, verifying a residential service load under NEC 2023 / 2026 standards, or checking an IEC metric cable run in square millimeters, Wirebench Pro surfaces the exact governing code rule and intermediate math rather than hiding them behind a black-box result.
Engineering calculation methodology
All 24 calculators and 6 reference charts read from a single audited calculation engine (assets/nec-core.js) verified by automated unit and boundary test suites. No table value is ever hardcoded inside an individual page.
| Standard / Table | Engineering scope | Implementation details |
|---|---|---|
| NEC Table 310.16 | Conductor ampacity (60 °C, 75 °C, 90 °C) | Full 24-size copper (14 AWG to 1000 kcmil) and aluminum (12 AWG to 1000 kcmil) tables with NEC 110.14(C) terminal caps and 240.4(D) small-conductor limits. |
| NEC 310.15(B) & (C)(1) | Ambient & bundling derating | Temperature correction factors above and below 30 °C (86 °F) combined with raceway current-carrying conductor adjustment factors. |
| NEC Chapter 9 Tables 1, 4, 5 | Conduit fill & raceway sizing | 53% (1 wire), 31% (2 wires), 40% (3+ wires), and 60% nipple fill limits across EMT, PVC Sch 40/80, RMC, IMC, FMC, and LFMC. |
| NEC Chapter 9 Tables 8 & 9 | DC resistance & AC effective Z | Uncoated/coated DC resistance at 75 °C plus 60 Hz AC resistance and inductive reactance in PVC, aluminum, and steel raceways. |
| NEC Table 250.122 & 250.122(B) | Equipment grounding conductors | Base EGC sizing from OCPD rating (15 A to 6000 A) plus automatic proportional circular-mil upsizing when phase conductors increase for voltage drop. |
| NEC 2023 Art. 220 / 2026 Art. 120 | Dwelling service load calculations | Standard and Optional Method (220.82 / 120.82) residential service and feeder demand calculations, including HVAC, cooking, dryer, and EVSE loads. |
| IEC 60228 | Metric conductor sizes & resistance | 18 standard metric cross-sections (1.5 mm² to 500 mm²) with 20 °C to 75 °C temperature-adjusted resistance and conservative AWG ampacity mapping. |
Commitment to zero-tracking, 100% client-side tools
Electrical engineers and contractors frequently calculate proprietary project schedules, feeder take-offs, and customer load profiles. Wirebench Pro is architected so that your project data stays strictly on your device:
- 100% client-side execution: Every calculation, table filter, and batch CSV import runs locally inside your browser's JavaScript runtime. No circuit parameters or uploaded CSV schedules are ever transmitted to a backend server.
- No account walls or gated results: All 24 calculators, worked examples, materials take-offs, and printable field reports are freely accessible without registration or email capture.
- Minimal local preferences: Only two non-identifying preference keys (nec.theme for daylight/dark mode and nec.units for US/IEC units) are stored in browser localStorage.
- Offline-ready static architecture: Built with zero third-party JavaScript frameworks and zero build-step bloat for instant load times on job-site cellular connections.