Wire size and voltage drop calculators
24 calculators and 6 NEC reference charts. Everything runs in your browser; nothing is sent to a server.
Instant wire and voltage drop quick-check
A
ft
V
Phase
Material
Assumes a 90 °C conductor (THHN) on 75 °C terminals, 86 °F30 °C ambient, up to 3 current-carrying conductors, a resistive load, and Chapter 9 Table 8 conductor resistance. IEC sizes use the ampacity of the largest AWG size that does not exceed their area.
Voltage drop
No result
—
%
Enter a load, length and voltage to see the result.
- Volts lost
- —
- Voltage at the load
- —
- Ampacity of this wire
- —
- Smallest wire for 3% drop
- —
Tool directory
24 calculators, 6 charts
No tool matches that filter. Try a shorter word such as “wire” or “panel”.
Core conductor and voltage drop tools
6 tools
Wire size calculator
Smallest conductor for a load, checked against ampacity, terminal rating and voltage drop.
NEC 310.16
Voltage drop calculator
Volts and percent lost over a run: single-phase, three-phase or DC.
Ch. 9 Table 8, 9
Ampacity and derating calculator
Ampacity after ambient temperature and conductor bundling adjustments.
NEC 310.15(B)
Maximum wire length
Longest run a given wire can carry before the drop passes your limit.
Ch. 9 Table 8
Wire resistance calculator
Resistance, reactance and impedance for any size, length and conduit type.
Ch. 9 Table 8, 9
AWG to mm² converter
Convert between AWG, kcmil and IEC mm² with area and circular mils.
IEC 60228
Conduit, breaker, panel and power tools
6 tools
Conduit fill calculator
Percent fill for mixed conductors in EMT, PVC Schedule 40 and 80, or rigid conduit.
Ch. 9 Table 1, 4, 5
Conduit size calculator
Smallest trade size that holds a set of conductors within the fill limit.
Ch. 9 Table 4
Breaker size calculator
Standard breaker or fuse rating for a load, with continuous-load and conductor limits.
NEC 240.4, 240.6
Grounding conductor size
Equipment grounding conductor size from the overcurrent device rating.
NEC 250.122
Load calculation
Dwelling service size using the NEC optional method.
NEC 220.82
Amps, kW, kVA and hp converter
Convert between amps, kW, kVA and horsepower for single-phase, three-phase and DC.
P = V × I
Advertisement
Specialized equipment: EV, solar, motor, transformer, batch
6 tools
EV charger circuit
Wire, breaker and ground for Level 2 charging at 125% continuous load.
NEC 625.40
Solar PV conductors
PV source and output circuit conductors and protection with the 690.8 current factors.
NEC 690.8
Motor circuit
Conductors, overload and branch protection from motor full-load current.
NEC 430.22
Transformer protection
Primary and secondary overcurrent protection and conductor sizes for a transformer.
NEC 450.3
DC and battery cable
Cable size for battery, inverter and low-voltage DC runs by current and drop.
Ch. 9 Table 8
Batch CSV sizing
Size many circuits at once: paste or load a CSV, review the results, export a CSV.
NEC 310.16
DIY and contractor projects, with NEC reference charts
6 tools, 6 charts
Subpanel feeder
Feeder wire, breaker and ground for a garage or outbuilding subpanel.
NEC 250.32
Range and dryer circuit
Wire and breaker for electric ranges and dryers, using demand loads.
NEC 220.55
Hot tub and spa circuit
Wire, GFCI breaker and bonding for a spa or hot tub circuit.
NEC 680.43
Well pump wire
Wire size and drop for a submersible pump from horsepower and well depth.
NEC 430
Generator inlet and cord
Inlet, cord and breaker sizing for a portable generator connection.
NEC 445.13
Wire cost comparison
Compare copper and aluminum cost per run with drop and ampacity checks.
NEC 310.16
NEC reference charts
Advertisement